Schier grease traps gb-75 pdf

Pace supply great basin grease interceptor, 616 lb, 75. It can easily be attached to any of the three outlets provided to ease job site piping layouts. Schier great basin long riser extension system, for use with. Grease interceptors grease traps, grease trap types. Gb250 100 gpm poly grease trap interceptor with 4 outlet great basin high efficiency grease interceptor features. The article describes traditional gravity and baffle operated grease traps, hydromechanical grease traps, and automatic grease removal units or agrus.

This application has not been configured for a device of this screen size. All grease interceptors have a maximum grease holding capacity. Please either make your screen larger or use a different device. Gb75 75 gpm grease interceptor for indooroutdoor use.

Great basin model gb35, gb50, gb75 and gb250, sewer viewer models sv24l4 and sv24o4, foot model grease interceptor, molded polyethylene, 2434 in dia x 35516 in l, domestic. While it is physically smaller than traditional outdoor gravity grease interceptors, the great basin provides proven grease storage capacities far exceeding those of the much larger units. Schier gb75 great basin grease interceptor, 616 lb, 75 gpm. Gb 75 gb 250 grease capacity lbs 98 98 98 98 98 98 98 98 98 98 98 259 259 616 1,076 for indoor installations patg2025 patg2025 patg3050 patg3050 gb 75 gb 75 gb 250 gb 250 gb 75 2. Drainnet offers the very best in grease trap grease interceptor technology. A correctly sized grease interceptor reduces maintenance costs for restaurants and prevents the chance of a messy and costly overflow. Gb75 75 gpm poly grease trap interceptor with 4 outlet great basin high efficiency grease interceptor features. Interceptor shall be furnished for above or below grade installation.

Schier grease interceptors are not to be installed in any other manner except as shown. Schier great basin grease interceptor, high capacity, series. Pumpout port compatibility use pumpout port pp2 for legacy gb75 models pre april 2019 with serial number 2019 4955 or below. This was installed in place of the original 1,000 gallon. We help restaurants, cafeterias, hospitals, food processing plants, hotels, and commercial kitchens keep fogs fats, oils, and grease our of their plumbing system and meet the standards set by local authorities. Onfloor, buried or lowprofile undersink installation. Schier c24hp schier c24hp gasketed pickable cover, for use with great basin model gb50, gb75 and gb250 grease interceptor, all big foot model gravity grease interceptor and sewer viewer model sv24l4 and sv24o4 sampling port, 24 in, cast iron, gray, domestic. Use pumpout port pp3 for legacy gb 75 models from april 2019 to april 2020 and new gb 75 models after april 2020. Schier gb75 great basin grease interceptor, 616 lb, 75. A polypropylene grease trap, model number gt25, as certified by the plumbing and drain institute. Schier grease interceptors are not to be installed in any other manner except as. Special order extensions are available for units to meet grade level. Schier gb75 schier gb75 great basin grease interceptor, 616 lb, 75 gpm, 4 in plain end inlet x 4 in plain end outlet.

This product can expose you to chemicals such as lead, carbon black, nhexane, methyl isobutyl ketone, nickel, bisphenol a, naphthalene, talc, vinyl chloride, formaldehyde gas and titanium dioxide, which are known to the state of california to cause cancer and birth defects or other reproductive harm. Gb 75 installation guide page 3 of 8 the wet weight of the interceptor combined ags2 with high temperature kitchen water creates the potential for tank deformation. To prevent this, grease traps and interceptors have to be regularly maintained by having a permitted liquid waste hauler remove both the top grease layer and the bottom solids. Application of grease production sizing method example 1.

While it is physically smaller than traditional outdoor gravity grease interceptors, the great basin provides proven grease storage capacities far exceeding those of. Gb 250 100 gpm poly grease trap interceptor with 4 outlet great basin high efficiency grease interceptor features. If you run a restaurant or operate a commercial kitchen, this solution will keep grease from building up in your pipes and your business turning out quality service as usual. Grease trap is corrosionresistant coated fabricated steel with nohub connections, flow diffusing baffle, integral trap, and vented inlet flow control device. When it comes to sizing grease interceptors, many plumbing codes focus on either flow rate or liquid volume. Plastic grease trap 75 gpm interceptor for grease separation. Great basin model gb35, gb50, gb75 and gb250, sewer viewer models sv24l4 and sv24o4, foot model grease interceptor, molded polyethylene, 2434 in dia x 2012 in l, domestic. Schier grease interceptor gb 75 keyword found websites. Jan 27, 2020 new orleans grease trap cleaning and cooking oil recycling offers reasonably priced grease trap and inkitchen grease interceptor cleaning and used cooking oil recycling services to customers in the greater new orleans, metairie, kenner, and west bank areas. Gb75 gb250 grease capacity lbs 98 98 98 98 98 98 98. The big dipper automatic grease and oils removal system takes the guesswork out of grease recovery. Schier sized a great basin gb250 grease interceptor which has a 3 rd party proven grease storage capacity of 1,076 grease lbs. The gt2700 series grease interceptors carry the standard zurn oneyear. Oct, 2015 75 gpm 616 grease lbs hydromechanical grease interceptor.

Grease production sizing method western states alliance. Schier products is the manufacturer of the grease interceptors that are listed in accordance with section 1003. Schgb75 great basin grease interceptor, 616 lb, 75 gpm, 4 in plain end inlet x 4 in plain end outlet. We used schier to replace 74 rusting steel grease traps at buccaneers stadium and saved roughly 90 minutes per unit versus installing another steel unit.

Its ideal for kitchens and sites that want to protect internal plumbing from grease buildup and manage their own grease recovery instead of relying on a third party to clean the unit which could cost thousands of dollars per year. Cover shall provide watergastight seal and have minimum 450 lbs. For new construction or replacement of failed steel interceptors, the great basin tm series offers the best design for most indoor installation, with superior flow pattern, fog capacity, and grease retention. Great basin series outdoor grease interceptors feature trafficrated covers. Pumpout port compatibility use pumpout port pp2 for legacy gb 75 models pre april 2019 with serial number 2019 4955 or below. Gb75 gb75 75 gpm poly grease trap interceptor with 4. Pace supply great basin grease interceptor, 616 lb, 75 gpm. Schier indoor grease interceptor inlet and outlet diffusers. See more ideas about recycling services, grease and new orleans. Home schier greese interceptors schier gb75 poly grease trap interceptor. This grease trap is different from traditional metal grease traps since it is made of a durable, seamless polyethylene material that will. This product may be used in place of model gb50 indoor installations only. Great basin indoor high capacity grease interceptor. All of schier s products are proudly made in the u.

Schier great basin grease interceptors gb250, gb75, gb50, gb35. Consult local gb 35 interior only, gb 50, gb 75, gb 250 schier grease interceptors are rated and manufactured with an internal flow control system already in interior or exterior below grade installation instructions place. Schier grease interceptors meet or exceed the asme a 11214. Out of stock usually ships within 7 days global availability in stock. Model gb500 uses model ak2 anchor kit for use with deadmen anchors. Grease capacity see below meals per day grease production values below see operating days per pumpout cycle model gb15 gb20 gb25 gb35 gb50 gb75 gb250 maximum grease capacity lbs. Schier great basin lr24 long riser extension system with. Grease interceptor, indooroutdoor, 4 inch connection, plain end connection, 3812 inch height, 46 inch length, 32 inch width, polyethylene, 616 lb capacity, 75 gpm flow rate, temperature rating. Gb250 gb250 100 gpm poly grease trap interceptor with 4. Size, type, and location of grease traps shall be in accordance with the manu facturers instructions and the requirements of city of carrollton ordinances. Schier considers both flow rate and grease production to determine the capacity of the interceptor and. Gb series, 4 in inlet connection, 4 in outlet, 1076 lb, 100 gpm, plain, polyethylene, 5112 in h x 68 in w x 3312 in d, domestic. The gb1 can be installed as a 20 or 25 gpm interceptor, and can be set on the floor or buried.

Great basin, 4 in plain end inlet connection, 4 in plain end outlet, 616 lb, 75 gpm, polyethylene, 46 x 3812 x 32 x 26 x 1212 in. Schier gb75 description schier grease interceptor, series. Gt2700 grease interceptor recommended for removing and retaining grease from wastewater in kitchen and restaurant areas where food is prepared. Schier great basin short riser extension system, for use with. Consult local gb35 interior only, gb50, gb75, gb250 schier grease interceptors are rated and manufactured with an internal flow control system already in interior or exterior below grade installation instructions place. Choose options schier great basin gb250 indooroutdoor high capacity grease interceptor. Click here to register to take advantage of our full site capabilities, and access your custom pricing to view columbia pipe list prices, please scroll to the bottom of this page. Schier gb2 indoor grease interceptor inlet and outlet diffusers. The gb2 can be installed as a 35 or 50 gpm interceptor, and can be set on the floor or buried.

This product may be used in place of models gb50 and gb 75 indoor installations only. It traps grease inside the unit without risk of corrosion, clogging or cross contamination. Grease interceptor sizing sean duffy, schier products. Use pumpout port pp3 for legacy gb75 models from april 2019 to april 2020 and new gb75 models after april 2020. Gb 75 75 gpm poly grease trap interceptor with 4 outlet great basin high efficiency grease interceptor features. It can easily be attached to any of the three outlets provided to ease jobsite piping layouts. Grease traps like the watts gi75k are often used with cooking or prep sinks, pot sinks, and commercial dishwashers in various types of commercial food.

1161 1317 315 1106 329 1506 608 795 325 506 1371 619 180 348 1304 820 952 670 757 1316 1276 558 895 600 1211 434 581 741 478 1549 142 1244 713 520 678 309 979 1344 465 273 1477 631 836 1371 195 307